Power Factor Correction

PFC BR 4000 ER

Characteristics

  • Intelligent control
  • Menu driven handling in English language
  • Test-run possible
  • Large voltage measuring range
  • Recall function of recorded values
  • Four-quadrant operation
  • Potential free contact alarm output (Optional)
  • RS485 communication interface (Optional)
  • Real Time Clock (Optional)

Display
  • Large and multifunctional LCD (2 × 16 characters)
  • Graphic and alphanumeric
  • LCD illumination
System parameters displayed
  • Line voltage (V AC)
  • Reactive power (kvar)
  • Active power (kW)
  • Frequency
  • Apparent power (kVA)
  • Apparent current (A)
  • Temperature (°C)
  • Real-time cos phi
  • kvar value to target cos phi
  • THD – V / THD - I in % upto 31st
  • Individual Harmonics in % upto 31st for V & I
  • Energy kWh (Import/ Export)
  • Energy kVAh
  • Energy kVARh (Inductive / Capacitive)
  • Demand kVA /Current
  • Run Hour – Number of hours load is connected
  • On Hour – Hours for which power supply is ON
  • No of interruption – Number of interruption for power supply.
Alarm output
  • Out of Bank (Under Compensation)
  • Overcompensation
  • Under Voltage
  • Over Voltage
  • Undercurrent
  • Overcurrent
  • Over temperature
  • Under / Over Frequency
  • Excess Harmonics ( V-THD / I-THD)
Recall recorded values
  • Maximum / Minimum Voltage
  • Maximum / Minimum Current
  • Maximum / Minimum Frequency
  • Maximum / Minimum Active Power
  • Maximum / Minimum Apparent Power
  • Maximum / Minimum Reactive Power
  • Maximum / Minimum Temperature
  • Maximum / Minimum THD(V/I)
  • Switching count of Capacitor
  • Operation time of capacitor
Warning Messages
  • Capacitor switching count exceed the limit
  • Capacitor Health Fault

Weight 0.35 kg
Case Panel-mounted instrument, 96 × 96 × 51 mm (Back Depth 70mm with add on module) (cut out 92 +0.8× 92+0.8 mm)
Ambient conditions
Over-voltage class III
Pollution degree 2
Operating temperature –10 ... +60 °C
Storage temperature –20 ... +65 °C
Sensitivity to EMC IEC61326-1
Safety guidelines IEC 61010-1:2010
Mounting position Flush Mounting
Humidity class 15% … 95% non-condensing
Protection class
Front plate IP54 to IEC60529
Rear side IP20 to IEC60529
Operation
Auxiliary Supply voltage 110 V AC – 550VAC
Auxiliary Supply Frequency 40 to 70 Hz
Target cos phi 0.8 ind. … 0.8 cap.
Switching On & Off 10 s … 30 min
Discharge Time 60 s … 30 min
Control modes self-optimized intelligent control mode
Measurement
Measurement voltage range 30 ... 550 V AC (L–L / L–N)
Fundamental frequency 45 and 70 Hz
Measurement current (CT) x/5 and x/1 Ampere onsite programmable
Minimum operating current 2 mA
Maximum current 6 A (sinusoidal)
Accuracy Current, voltage: 0.5% of nominal value
Active, apparent power: 1% of nominal value
Active Energy : 1%
Apparent Energy : 1%
Reactive Energy : 2%
THD : ± 4%
Switching outputs
Relay outputs
Number of outputs 4 / 6 / 8 steps available
Switching voltage/Power Max. 250 VAC / 1000W
Alarm relay Potential-free contact (Max. 250 VAC / 1000W)

Type Voltage Output Relay Alarm output Interface (RS485) RTC Ordering code
50/60 Hz
BR4000-ER 240 4 Yes No No B44066R4004R240
BR4000-ER 240 6 Yes No No B44066R4006R240
BR4000-ER 240 8 Yes No No B44066R4008R240
BR4000-ER 240 4 Yes Yes No B44066R4014R240
BR4000-ER 240 6 Yes Yes No B44066R4016R240
BR4000-ER 240 8 No Yes No B44066R4118R240
BR4000-ER 240 4 Yes Yes Yes B44066R4024R240
BR4000-ER 240 6 Yes Yes Yes B44066R4026R240
BR4000-ER 240 8 Yes No Yes B44066R4038R240
BR4000-ER 240 8 No Yes Yes B44066R4128R240

Controller hunting: When putting the capacitor bank into operation, it is required to avoid needless switching cycles (means permanent switching on and off of steps without significant change of consumer load). This so called “controller hunting“ would increase the number of switching operations of the connected contactors and capacitors and decrease the expected life cycle (wear out) and, in worst case, capacitor bursting and fire, etc . This can be avoided by a proper programming of the BR4000-ER with the actual system parameters (current transformer prim. and sec., Nominal Voltage, kvar steps, capacitor switching threshold, switching time).

Accessory for PF-Controller BR4000-ER

For add on Relay block & RS485 module should be ordered separately.

Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications.

Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.