News
...
Power Factor Correction

PFC BR 6000

Characteristics

  • Intelligent control
  • Menu driven handling (plain language; Czech/Dutch/German/English/French/Polish/ Portuguese/Russian/Spanish/Turkish)
  • Self-optimizing control capability
  • Automatic initialization
  • Test-run possible
  • Large voltage measuring range
  • Recall function of recorded values
  • Four-quadrant operation (e.g. stand by generator)
  • Powerful alarm output
  • 2nd parameter set
  • 13 steps possible with version /S
  • Control series editor
  • Detailed expert modes

Display
  • Large and multifunctional LCD (2 × 16 characters)
  • Graphic and alphanumeric
  • LCD illumination
System parameters displayed
  • System voltage (V AC)
  • Reactive power (kvar)
  • Active power (kW)
  • Frequency
  • Apparent power (kVA)
  • Apparent current (A)
  • Temperature (°C )
  • Real-time cos phi
  • Target cos phi
  • Kvar value to target cos phi
  • Harmonics (3rd … 19th) V (%), I (%)
  • Energy (Kvar)
Alarm output
  • Insufficient compensation
  • Overcompensation
  • Undercurrent
  • Overcurrent
  • Over temperature
  • Harmonics
  • Threshold value programmable
  • Internal error storage
  • 2nd signal relay random
Recall recorded values
  • Maximum voltage (Vmax)
  • Minimum voltage
  • Maximum reactive power, Q (Kvar)
  • Maximum active power, P (kW)
  • Maximum apparent power, S (kVA)
  • Maximum temperature (°C)
  • Maximum THD-V/THD-I
  • Switching cycles of capacitors
  • Operation time of capacitors

Weight 1 kg
Case Panel-mounted instrument, 144 x 144 x 55 mm (cut out 138 x 138 mm)
Ambient conditions
Over-voltage class III
Pollution degree 2
Operating temperature -20 ... +60 °C
storage temperature -20 ... +75 °C
Sensitivity to inference (industrial areas) EN55082-2.1995
spurious radiation (residential areas) EN55011 10.1997
Safety guidelines IEC 61010-1:2001, EN 61010-1:2001
Mounting position Any
Humidity class 15 … 95% without dew
Protection class
Front plate IP54 according to IEC60529
Rear side IP20 according to IEC60529
Operation
Supply voltage 245 V AC ±20%, 50/60 Hz
Target cos phi 0.3 ind. … 0.3 cap.
Switching and discharge time range 1 s … 20 min
Number of control series 20 series preset + control series editor for free programming
control modes Series switching (LIFO),
circular switching (FIFO),
self-optimized intelligent control mode
Measurement
Measurement voltage range 30 ... 525 V AC (L–L / L–N)
Fundamental frequency 50 and 60 Hz
measurement current (CT) x/5 and x/1 Ampere possible
Minimum operating current 40 mA / 10 mA
Maximum current 5.3 A (sinusodial)
Zero voltage release < 15 ms
Accuracy Current, voltage: 1% Reactive, active, apparent power: 2%
Switching Outputs
Relay outputs
Number of outputs 6/7 or 12/13 steps available
Switching voltage/current Max. 250 V, 6 A
Message relay Potential-free contact (max. 250 V, 6 A) Parameters programmable

Type Voltage Output Alarm output Switchover 2nd parameter set Interface Ordering code
50/60 Hz Relay Transistor
BR6000-R6 230 6 - Yes No No B44066R6006R230
BR6000-R12 230 12 - Yes No No B44066R6012R230
BR6000- R12/S485* 230 12 - Yes Yes RS485 B44066R6412R230

* including new Windows-Software V5.0

  • Controller hunting: - When putting the capacitor bank into operation, it is required to avoid needless switching cycles (means permanent switching on and off of steps without significant change of consumer load). This so called “controller hunting“ would increase the number of switching operations of the connected contactors and capacitors and decrease the expected life cycle (wear out) and, in worst case, capacitor bursting and fire, etc . This can be avoided by a proper programming of the BR6000 with the actual system parameters (current transformer prim. and sec., first kvar step, control series, switching time).
  • Accessory for PF-Controller BR6000
    • USB to RS485 converter to connect BR6000-R12/S485 to a PC, ordering code B44066R3333E230
    • Data logger "DataLog SD" für BR6000, ordering code B44066R1311E230
    • Multi measuring interfaces MMI6000/MMI7000 for real current measuring Technical data see separate data sheets.
  • Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.