Characteristics

  • Intelligent control
  • Menu driven handling (plain language) Czech/Dutch/English/French/German/Polish/Portuguese/Russian/ Spanish/Turkish
  • Self-optimizing control capability
  • Large measuring voltage range
  • Recall function of recorded values
  • Four-quadrant operation (e.g. stand by generator)
  • Powerful alarm output
  • Control series editor (value perception selectable)
  • High precision of measurement
  • 2nd expert mode
  • Fixing of net frequency in the expert mode (for measuring) to avoid errors when measuring in critical grids
  • Auto-range-function for sensitivity: For input current <1A the amplification is increased in order to reach a sensitivity of 20 mA.

Display
  • Large and multifunctional LCD (2 × 16 characters)
  • Graphic and alphanumeric
  • LCD illumination
System parameters displayed
  • System voltage (V AC)
  • Reactive power (kvar)
  • Active power (kW)
  • Frequency
  • Apparent power (kVA)
  • Apparent current (A)
  • Temperature (°C / °F )
  • Real-time cos ∅
  • Target cos ∅
  • Switchover cos-∅ / tan-∅
  • kvar value to target cos ∅
Alarm output
  • Insufficient compensation
  • Overcompensation
  • Undercurrent
  • Overcurrent
  • Overtemperature
  • Threshold value programmable
  • Internal error storage
  • 2nd signal relay random
  • Triggering time programmable
Recall recorded values
  • Maximum voltage, (Vmax)
  • Maximum reactive power, Q (Kvar)
  • Maximum active power, P (kW)
  • Maximum apparent power, S (kVA)
  • Maximum temperature (°C)
Dynamic PFC
  • Direct triggering of thyristor modules series TSM

Weight 1 kg
Case Panel-mounted instrument, 144 x 144 x 55 mm (cut out 138 x 138 mm)
Ambient conditions
Over-voltage class III
pollution degree 2
Operating temperature -20 ... +60 °C
storage temperature -20 ... +75 °C
Sensitivity to inference (industrial areas) EN55082-2.1995
spurious radiation (residential areas) EN55011 10.1997
Safety guidelines IEC61010-1:2001, EN61010-1:2001
Mounting position Any
Humidity class 15 … 95% without dew
Protection class
Front plate IP54 according to IEC60529
Rear side IP20 according to IEC60529
Operation
Supply voltage 110 … 230 V AC, 50 and 60 Hz power lines
Target cos φ 0.3 inductive to 0.3 capacitive adjustable
Switching and discharge time range 20 … 1000 ms
Number of control series 20 series preset + control series editor for free programming
Series switching (LIFO),
circular switching (FIFO)
control modes Self-optimized intelligent control mode
Measurement
Measurement voltage range 30 ... 525 V AC (L-N) or (L-L)
Fundamental frequency 50 and 60 Hz
measurement current (CT) x/5 and x/1 Ampere possible
Minimum operating current 40 mA / 10 mA
Maximum current 5.3 (sinusodial)
Zero voltage release < 15 ms
Switching Outputs
Transistor outputs- Number of outputs 6
Switching voltage/power 10 … 24 V DC
Alarm relay Potential-free contact (max. 250 V, 6 A)
Ordering code B44066R6106R230N1

The ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, on the EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes

  • Controller hunting: - When putting the capacitor bank into operation, it is required to avoid needless switching cycles (means permanent switching on and off of steps without significant change of consumer load). This so called “controller hunting“ would increase the number of switching operations of the connected contactors and capacitors and decrease the expected life cycle (wear out) and, in worst case, capacitor bursting and fire, etc . This can be avoided by a proper programming of the BR6000 with the actual system parameters (current transformer prim. and sec., first kvar step, control series, switching time).
  • Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications.
  • Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.