MultiJet
Retrofit-1 Fixed MBus NBIoT
System Overview
- HANBIT is known for its Smart Metering Solutions for Water and Gas metering industries, has actually started providing retrofit AMR solutions to global brands in respective metering markets. Its been a decade of experience in delivery retrofit AMR, with latest (upgraded) standards and technologies
- Meter interface: Magnetic ( reliable, rugged & low current with IP68 protection).
- The output of corresponding meter is directly connected to IP68 protected AMR gadget, the running count of the consumption is stored in local memory, (Permanent Storage) with programmable intervel optional.
- The system offers different Open Metering Standard protocols NB-IoT. The battery operated models comes with minimum 5 years battery life depending on the end use requirement and geographical conditions.
- The system programmable to work in any frequency of global NB-IoT Bands i.e., B1, B3, B8, B18, B19, B26 the wireless communication range starts with 500 meters to 5kms.
- The state-of-the-art two way communication allows to configure settings of each AMR as per client requirement.
Frequency Bands | Operating temperature | Specifications | Highlights |
---|---|---|---|
US: - eMTC: B2, B4, B12, B13 | -40°C to +85°C | Data: LTE eMTC, Max. 375Kbps(DL), Max. 300Kbps(UL) | Low power consumption |
CN: - NB-IoT: B1, B3, B5, B8 - eMTC: B1, B3, B5, B8, B39 - GSM/GPRS/EDGE: 900/1800 MHz |
3.3 to 4.3 V (DC), 3.8 V recommended | NB-IoT | Deep coverage |
CA:- NB-IoT/eMTC: B3, B5, B8 | 3GPP Rel-13 | Max. 32Kbps(DL) | |
EU: - NB-IoT/eMTC: B3, B8, B20 - GSM/GPRS/EDGE: 900/1800 MHz |
CMUX | Max. 72Kbps(UL) |
Meter Data Format
- 4 Byte Hexadecimal Value
- NFC configurable
- Decimal equivalent value of 4 byte(hex) is Meter index
Tamper Data Format
- 1 Byte Hexadecimal Value
- NFC configurable , for Clear
- Tamper
0x00 ---No Tamper
0x01 ---Box Open
Battery Voltage Data Format
- 1 Byte Hexadecimal Value
- 0x00 to 0x7F
- Battery voltage value can be calculated for getting Max Voltage measured on the battery.
- The Android Mobile Phone with NFC feature for Remote Configuration Having read the meter, the data can be sent to the central control room.
- Unique ID
Configurable using NFC mobile application, Unique to the Network ID for registering to the Network Operator can be identified with this ID.
- Data Transmission Interval
Configurable parameter through NFC for setting its time interval for Transmission of data to the Gateway, with this configured interval will be saved. Device will communicate in this regular interval.
- Configurable RTC
Real Time Clock can be set into device through NFC, can be read and updated for real time operation.